Skip Navigation


The Computer Journal Advance Access originally published online on January 18, 2007
The Computer Journal 2007 50(2):217-231; doi:10.1093/comjnl/bxl064
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
50/2/217    most recent
bxl064v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Thomasian, A.
Right arrow Articles by Ng, S. W.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2007. Published by Oxford University Press on behalf of The British Computer Society. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Analysis of Rebuild Processing in RAID5 Disk Arrays

Alexander Thomasian1,*, Gang Fu1 and Spencer W. Ng2

1 Computer Science Department, New Jersey Institute of Technology, Newark, NJ 07102, USA
2 Hitachi Global Storage Technologies, San Jose Research Center, San Jose, CA, USA

* Corresponding author: alexthomasian{at}gmail.com

Received 15 December 2005; revised 12 October 2006

RAID5 tolerates single disk failures by exclusive-ORing (XORing) the blocks corresponding to a requested block on the failed disk to reconstruct it. This results in increased loads on surviving disks and degraded disk response times with respect to normal mode operation. Provided a spare disk is available, a rebuild process systematically reads successive disk tracks, XORs them to recreate lost tracks and writes them onto a spare disk, thus returning the system to its original state. Rebuild time is important since RAID5 disk arrays with a single disk failure are susceptible to data loss if a second disk fails. According to the vacationing server model (VSM), rebuild read requests on surviving disks are given a lower priority than external user requests, so as to have less impact on their response time. Given that disk loads are balanced due to striping, rebuild time can be approximated by the time to read the contents of any one of the surviving disks. The analysis of the M/G/1 queueing model of VSM, given in this article, is more accurate and yet simpler than a previous analysis, but it also takes into account the effect of disk zoning explicitly. We also present a heuristic method to estimate rebuild time, which can be combined with the new analysis. The ability to quickly and accurately estimate rebuild time is useful in computing the reliability of RAID5 systems, especially during design tradeoff studies. The accuracy of the various analyses to estimate rebuild time are checked against detailed simulation results.

Key Words: Disk arrays • RAID5 • rebuild processing • rebuild time • M/G/1 queueing system • vacationing server model • zoned disks


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.